Administer Fiber Links
6. The Fiber Link Administration form appears. On Page 1 of the form:
a. Enter the Board Location: for Endpoint-1 and Endpoint-2. This
b. The Board Type field is display only and shows the type of circuit
c. In the DS1CONV Board Location: field, enter the cabinet, carrier,
d. The DS1CONV Board Type: field is display only and shows the
e. In the Is one endpoint remoted via a DS1 Converter
7. On Page 2 of the form:
a. Administer the A-PNC DS1 Converter (DS1CONV) Attributes.
b. Enter the DS1 Converter Facilities information. In the Facility
c. In the Bit Rate
d. Enter the idle code in the Idle Code MSB (1) . . . . LSB
e. Enter the appropriate data in the Line Coding: field. This data
f. Scroll to Page 3 and modify the fields as needed for the B-PNC.
555-233-115
is the cabinet, carrier, and slot that identifies the physical location of
an SNI or EI circuit pack that is the first endpoint of the fiber link.
Repeat for the remaining endpoints.
pack in Endpoint-1.
and slot that identifies the physical location of DS1 Converter circuit
pack in the first endpoint of the duplicate fiber link. Endpoint-1's
duplicate along with Endpoint-2's duplicate make up the duplicate
fiber link called the B-PNC link.
type of DS1 Converter circuit pack in Endpoint-1. The circuit pack
type in Endpoint-1 (A-PNC) and Endpoint-1 (B-PNC) must match.
Complex? field, type y to specify that a DS1 Converter complex is
used to remote 1 endpoint. If y is entered, administer the A-PNC
DS1 Converter Board Location on Page 1. The A-PNC DS1
Converter Board Type displays.
Installed? field, type y for all installed facilities (A, B, C, and D).
:
field, type 1.544 for T1 operation or 2.048 for E1
operation.
NOTE:
One bit rate applies for all facilities within the same DS1
Converter complex. The Bit Rate: field displays only under
Facility A.
(8): field. The default value is 11101000. It is recommended that
the default value be used unless it becomes absolutely necessary to
change it. The "MSB" means Most Significant Bit, the "LSB" means
Least Significant Bit.
should match the line coding of the facility. For T1, example line
coding is b8zs. For E1, example line coding is hdb3.
NOTE:
If this data is not correct, wideband errors (such as multimedia
call handling) may occur.