Avaya DEFINITY Server R Manual page 176

Upgrades and additions
Hide thumbs Also See for DEFINITY Server R:
Table of Contents

Advertisement

Upgrading R5si/R6si to an Avaya DEFINITY Server R
EPN running Avaya MultiVantage Software
Figure Notes
1. Lightwave Transceiver
2. To PPN Carrier C Slot 1C02
3. To EPN 1 Carrier A Slot 2A01
(Cabinet Stack 2)
Figure 4-13. Fiber Optic Connections PPN to EPN1
For 1 or 2 Fiber-Remoted Expansion Port Networks
1. Behind port carrier C of the multicarrier PPN. See
4-14:
a. Install a lightwave transceiver on the connector at slot 1C02.
b. Connect a fiber optic cable to the transceiver just installed.
c. Route the fiber cable to the cabinet cable tray and out of the cabinet
d. Connect the fiber cable to the lightguide interface unit provided.
e. Carefully attach the fiber optic cable (with cable ties) to the wall of
4-50
Issue 5 October 2002
RX TX
2
1
NOTE:
Attenuators may be required for single mode fiber using a
300A Lightwave Transceiver
through the cable manager to the PDS cross-connect facility.
the cable tray at the built-in cable tie positions.
2
4. Fiber Optic Cable
5. TX Connector
6. RX Connector
Figure 4-12
1
cydff05 CJL 103196
and
Figure
555-233-115

Advertisement

Table of Contents
loading