Upgrading a Multicarrier G2 Universal Module to Avaya
DEFINITY Server R EPN running Avaya MultiVantage
Software
8. Connect the remaining end of the TDM/LAN cable (between the "A" and
"C" carriers) to the pin-field block marked "TDM" on the left side of the "A"
carrier.
9. On port carrier J58890BB-1, connect the TDM cable or TDM terminator to
Slot 02. On port carriers J58890BB-2 and J58890BB-3, connect the TDM
cables to Slot 01.
Table 5-9. TDM/LAN Connections
"J" Number
J58890BB-1
J58890BB-2
J58890BB-3
J58890AF
10. Install the front trim plate on the "A" carrier. Install the fan trim plate.
11. Install the power units (removed from G2 universal module) into the "A"
carrier. Do not interchange the physical locations of the units. The 631AR1,
631WA1, 631DA1, or 644A install in the left side, while the 631BR1,
631WB1, 631DB1, or 645B install in the right side.
12. If the expansion control carrier contains a 631BR1, 631WB1, or 645B
power unit, install the previously removed TN736 power unit in port slots
"18" and "19" of the carrier (adjacent to the 631BR1, 631WB1, or 645B). If
the system is equipped for neon message waiting, a TN752 or TN755
power unit must be used.
13. Connect the white power cords to the power units.
5-28
Issue 5 October 2002
Carrier Type
Port
Port
Port
EPN Control "A"
NOTE:
The TN736 is not required when the 631DB1 or 645B power unit is
used in the J58890AF-1 expansion control carrier or the J58890BB-2
or J58890BB-3 port carriers. It is required in the J58890BB-1 port
carrier, regardless of which 631 power unit is provided. Use the
TN752 or TN755 if the system contains neon message waiting.
LHS Slot
RHS Slot
21
02
21
01
21
01
21
02