Interconnect Port Networks with Fiber Optic Cabling
For a high reliability system with 2 DS1 Conv-remoted expansion port networks,
this arrangement requires:
6 DS1 Converter circuit packs (TN1654)
6 DS1 Converter-to-EI cables (846448637 and/or 846448645)
6 H-600-348 cables
3, 6, 9, or 12 pairs of CSUs
3, 6, 9, or 12 pairs of wall-field cables (provided with CSUs)
For 1 or 2 Collocated Expansion Port Networks
1. Behind port carrier C of the multicarrier PPN. See
4-13:
a. Install a lightwave transceiver on the connector at slot 1C02.
b. Connect 1 end of the appropriate fiber optic cable to the lightwave
c. Route the fiber optic cable from the lightwave transceiver to the
d. Carefully attach the fiber optic cable (with cable ties) to the wall of
2. Behind control cabinet A EPN stack 2:
a. Install a lightwave transceiver on the connector at slot 2A01.
b. Connect the other end of the fiber optic cable from the PPN to the
c. Carefully attach the fiber optic cable (with cable ties) to the rear
d. Coil up the surplus fiber optic cable, and place the coil either in the
555-233-115
NOTE:
Attenuators may be required for single mode fiber using a
300A Lightwave Transceiver
transceiver at slot 1C02.
cabinet's cable tray and down, out of the cabinet, to the EPN stack.
the cable tray at the built-in cable tie positions.
NOTE:
Attenuators may be required for single mode fiber using a
300A Lightwave Transceiver
lightwave transceiver at slot 2A01.
covers of the EPN stack.
cable manager or on the bottom shelf (holding the power supply) of
the PPN cabinet.
Figure 4-12