Avaya DEFINITY Server R Manual page 390

Upgrades and additions
Hide thumbs Also See for DEFINITY Server R:
Table of Contents

Advertisement

Adding New Carriers and EPN Cabinets
Reseat DEFINITY AUDIX System
1. Reseat the AUDIX assembly to its backplane connectors.
Power Up System
1. At each EPN, if present, set the main circuit breaker to ON.
2. At the PPN, set the main circuit breaker to ON.
3. The system performs the level 4 rebooting process, loading the system
program and default or current translations from the disk. Rebooting takes
5 to 11 minutes.
4. Type reset system 4 and press
removable media to memory.
5. Clear any alarms.
Install the License File
Pre-installation
1. Type save translation and press
After the translations have been copied (about 10 minutes), the system
returns an error code, which must be a zero; otherwise, the translations are
not copied.
2. Type reset system 3 and press
Wait until the system has completely reset before continuing.
3. If the system has IP endpoints registered, unplug the Ethernet cable from
the TN799 (C-LAN) circuit pack.
This disconnects (unregisters) all IP endpoints.
4. Type set time and press
Ensure that the system date and time are set correctly.
6-70
Issue 5 October 2002
NOTE:
Ignore alarms for now.
Enter
to copy the translations from
Enter
.
Enter
.
Enter
.
555-233-115

Advertisement

Table of Contents
loading

Table of Contents