Adding or Removing Cabinet Hardware
Hardware installation
!
WARNING:
To prevent electrostatic discharge (ESD), be sure to wear a grounding strap
while handling the circuit pack.
1. Remove connector (if any) from the back of the switch cabinet
corresponding to the TN2501AP circuit pack slot.
2. Insert the circuit pack into any port slot and close the latch securely.
At first, both the red and green LEDs are on steady, then the green LED
flashes. If there are announcements on the circuit pack, the amber LED
flashes while the announcements are copied from FLASH to RAM. After
approximately 3-5 minutes, all of the top 3 LEDs go out, although this time
is longer if there are announcements already recorded on the circuit pack.
3. Connect the Backplane Adapter
the back of the switch cabinet, corresponding to the TN2501AP circuit pack
slot.
4. Connect the LAN cable to the RJ-45 connector on the Backplane Adapter.
Switch administration after hardware installation
Use the following SAT commands to ensure that the system recognizes the
TN2501AP circuit pack and to administer its IP connections:
list configuration board
Use this command to ensure that the switch recognizes the TN2501AP circuit
pack after it is latched in the carrier slot.
1. At the SAT, type list configuration board board-location and press
RETURN
The System Configuration report appears.
7-44
Issue 5 October 2002
NOTE:
If the TN2501AP or TN750 circuit packs are at the system limit and
you insert a VAL circuit pack, the red LED on that circuit pack stays
on, indicating that the system does not accept it.
.
(Figure
7-4) to the Amphenol connector on
555-233-115