Avaya DEFINITY Server R Manual page 437

Upgrades and additions
Hide thumbs Also See for DEFINITY Server R:
Table of Contents

Advertisement

Downloading Firmware to Port Circuit Packs
Schedule download
1. Fill in every field in
field.
2. In the Target Location field, type the UUCSS address of each
similar-type, programmable circuit pack (up to 50).
555-233-115
Table 7-5 on page 7-14
NOTE:
If you are scheduling firmware downloads for a circuit pack that is
designated as primary/secondary sync (timing) source (for example,
TN464GP), this procedure automatically redesignates a local timing
source during the download. After the download is complete and the
circuit pack is returned to service, the procedure designates the
original circuit packs as the timing source.
NOTE:
The target circuit packs are automatically busied out before the
firmware is downloaded to them and automatically returned to service
after the download is completed. While a DS1 circuit pack is busied
out, any active calls through that circuit pack are dropped.
NOTE:
You can only download one image file to a similar type circuit pack at
a given time (for example, to every TN464GP circuit pack). The
download process does not support broadcasting more than one
image file to different-type circuit packs (for example, from TN464GP
to TN2313BP).
except the Target Location
Issue 5 October 2002