016-455 SMTP Server Time-out RAP
There is no response from the SMTP server within the specified time (60sec).
Initial Actions
Power Off/On
Procedure
If the time on the machine is incorrect, User Guide heading Changing the Default Time Set-
tings procedure resets the time. Or follow procedure below.
1.
Press the Log In/Out button on the control panel.
2.
Enter the Key Operator ID using the numeric keypad on the control panel. Select Confirm
on the System Administrator Login screen.
NOTE: The default Key Operator ID is (five one's) "11111". If the Authentication feature is
enabled, you may be required to enter a password. The default password is "x-admin".
3.
Select System Settings on the System Administrator Menu screen.
4.
Select System Settings on the System Settings screen.
5.
Select Common Settings on the System Settings screen.
6.
Select Machine Clock/Timers on the Common Settings screen.
7.
Select the required option.
8.
Select Change Settings.
9.
Change the value using the scroll buttons or select required options.
10. Select Save.
11. Return to main menu.
Status Indicator Raps
016-455, 016-456
016-456 SMTP time asynchronous RAP
A standard time synchronized source message and an asynchronous message was received
from the SMTP server.
Initial Actions
Power Off/On
Procedure
If the time on the machine is incorrect, User Guide heading Changing the Default Time Set-
tings procedure resets the time. Or follow procedure below.
1.
Press the Log In/Out button on the control panel.
2.
Enter the Key Operator ID using the numeric keypad on the control panel. Select Confirm
on the System Administrator Login screen.
NOTE: The default Key Operator ID is (five one's) "11111". If the Authentication feature is
enabled, you may be required to enter a password. The default password is "x-admin".
3.
Select System Settings on the System Administrator Menu screen.
4.
Select System Settings on the System Settings screen.
5.
Select Common Settings on the System Settings screen.
6.
Select Machine Clock/Timers on the Common Settings screen.
7.
Select the required option.
8.
Select Change Settings.
9.
Change the value using the scroll buttons or select required options.
10. Select Save.
11. Return to main menu.
February, 2008
2-188
Launch Version
WorkCentre 5225, 5230