012-280 (A-Finisher) Eject Home Sensor OFF Fail
BSD-ON:12.6
In the Eject Motor's initializing operation and ejecting operation, the Eject Motor had rotated
forward for a time corresponding to a specified qty of pulses since the Eject Home Sensor was
On, and then the motor stopped, but then the Eject Home Sensor was not detected turning Off.
Initial Actions
•
Check the Eject Home Sensor is properly installed, not broken and has no foreign object.
•
Power Off/ON.
Procedure
Check the Eject mechanism for a deformed or broken part and not-seated belts. The mecha-
nism is free from defects and belt damage.
Y
N
Repair the mechanism.
Enter Component Control [012-252]. Block and unblock the Eject Home Sensor with a piece of
paper. The display changes.
Y
N
Check the connections of
P/J8700
and P/J8725.
connected.
Y
N
Connect
P/J8700
and
P/J8725
Check for an open or short circuit between J8700 and J8725. The
J8700 and J8725 are OK.
Y
N
Repair the open or short circuit.
Measure the voltage between Finisher PWB J8700-9 (+) and GND (-). The voltage is
approx. +5VDC.
Y
N
Go to Wirenet A-Finisher +5VDC and check the +5VDC circuit.
Measure the voltage between Finisher PWB J8700-8 (+) and GND (-). Block and unblock
the Eject Home Sensor with a piece of paper. The voltage changes.
Y
N
Replace the Eject Home Sensor
Check the wires and connectors for an intermittent open or short circuit. If the problem
continues, replace the Finisher PWB
Enter [012-054] and [012-056] alternately. The Eject Motor rotates.
Y
N
Check the connections of
P/J8706
and P/J8741.
connected.
Y
N
Connect
P/J8706
and
P/J8741
A
B
Status Indicator Raps
012-280 (A-Finisher)
P/J8700
and
P/J8725
are securely
securely.
wires
(PL
22.10).
(PL
22.7).
P/J8706
and
P/J8741
are securely
securely.
A
B
Check for an open or short circuit between J8706 and J8741. The
J8706 and J8741 are OK.
Y
N
Repair the open or short circuit.
Measure the voltage between Finisher PWB J8706-13 (+) and GND (-), and between
J8706-15 (+) and GND (-). Each voltage is approx. +24VDC.
Y
N
Go to Wirenet A-Finisher +24VDC and check the +24VDC circuit. If the problem con-
tinues, replace the Finisher PWB
Replace the Eject Motor
(PL
22.7).
Check the wires and connectors for an intermittent open or short circuit. If the problem contin-
ues, replace the Finisher PWB
between
February, 2008
2-110
(PL
22.7).
(PL
22.9). If the problem continues, replace the Finisher PWB
(PL
22.7).
WorkCentre 5225, 5230
wires
between
Launch Version