Detailed Maintenance Activities (Hfsi); High Frequency Service Items - Xerox WorkCentre 5222 Service Manual

Tabloid black-and-white multifunction printer
Hide thumbs Also See for WorkCentre 5222:
Table of Contents

Advertisement

Detailed Maintenance Activities (HFSI)

Procedure
1.
Access Diagnostic Routines.
a.
Enter UI Diagnostics (Entering UI Diagnostics in
b.
Access Diagnostic Routines (Accessing Diagnostic Routines in
Mode).
2.
Select NVM Read/Write.
3.
Refer to
Table 1
and enter a counter number for any High Frequency Service Item (HFSI)
counters to be checked. Use the customer's output volume numbers to help determine
which HFSI components should be serviced. Consider components near threshold as
candidates for service.
4.
Refer to
Cleaning Procedures
for detailed cleaning instructions.
Table 1 High Frequency Service Items
Thres-
Counter
Name
hold
954-800
Tray 1 Feed counter
300K
954-801
Tray 2 Feed counter
300K
954-802
Tray 3 Feed counter
300K
954-803
MSI Feed counter
50K
954-804
HCF Feed/Retard/
300K
(7232/42)
Nudger
954-824
IBT Belt counter
480K
954-825
IBT Cleaner counter
100K
954-826
2nd BTR Counter
150K
954-830
K Developer Counter
420K
954-831
Y Developer Counter
420K
954-832
M Developer Counter
420K
954-833
C Developer Counter
420K
954-837
Xero Drum Counter
10M
954-842
Fuser Counter
10M
954-850
Deodorant Filter
5M
956-802
Lamp Scan Counter
6000K Replace the Exposure Lamp.
956-803
Exposure Lamp Time
7200K Replace the Exposure Lamp.
Counter
956-804
Exposure Lamp On
6000K Replace the Exposure Lamp.
Counter
955-806
CVT Feed Counter
200K
955-807
Simplex Feed Counter
912K
Service Call Procedures
Detailed Maintenance Activities
UI Diagnostic
Mode).
UI Diagnostic
Service Action to be performed
Replace the Feed Roll, Retard Roll, Nudger
Roll.
Replace the Feed Roll, Retard Roll, Nudger
Roll.
Replace the Feed Roll, Retard Roll, Nudger
Roll.
Replace the Feed Roll, Retard Pad.
Replace the Feed Roll, Retard Pad and
Nudger Roll
Replace the IBT Assembly.
Replace the IBT Cleaner.
Replace the Bias Transfer Roll.
Replace the K Developer.
Replace the Y Developer.
Replace the M Developer.
Replace the C Developer.
Replace the Xero Drum Assembly.
Replace the Fuser Assembly.
Replace the Deodorant Filter.
Replace the Document Nudger Roll, Feed
Roll, Retard Roll, Registration Roll.
Replace the Document Nudger Roll, Feed
Roll, Retard Roll, Registration Roll.
Table 1 High Frequency Service Items
Counter
Name
955-808
Duplex Feed Counter
955-810
Platen Interlock
Counter
955-829
Inverter Solenoid On
Counter
February, 2008
1-6
Thres-
hold
Service Action to be performed
912K
Replace the Document Nudger Roll, Feed
Roll, Retard Roll, Registration Roll.
260K
Replace the Platen Interlock Switch.
500K
Replace the Inverter Solenoid.
WorkCentre 5225, 5230