123-378 Interface Format RAP
There is an error in the data format sent from the Controller.
Initial Actions
Power Off/On
Procedure
Disconnect and reconnect the electrical connections on the UI PWB
the ESS PWB
(PL
9.2)
If the problem persists reload Software
(ADJ
If the problem persists replace the ESS PWB
Launch Version
WorkCentre 5225, 5230
(PL
11.2) and
P/J388
9.3.1).
(PL
9.2).
123-379 Dispatch RAP
The UI software failed.
Initial Actions
Power Off/On
Procedure
on
Disconnect and reconnect the electrical connections on the UI PWB
the ESS PWB
(PL
9.2)
If the problem persists reload Software
If the problem persists replace the UI PWB
If the problem persists replace the ESS PWB
February, 2008
2-655
(PL
11.2) and
(ADJ
9.3.1).
(PL
13.2).
(PL
9.2).
Status Indicator Raps
123-378 , 123-379
P/J388
on