012-260 Eject Clamp Home Sensor On Failure Rap - Xerox WorkCentre 5222 Service Manual

Tabloid black-and-white multifunction printer
Hide thumbs Also See for WorkCentre 5222:
Table of Contents

Advertisement

A
Y
N
Connect
P/J8878
and P/J8983.
Check the wire between J8878 and J8983 for an open circuit or a short circuit (BSD
12.22). The wire between J8878 and J8983 is conducting without an open circuit or
a short circuit.
Y
N
Repair the open circuit or short circuit.
Measure the resistance of the Eject Motor
(BSD 12.22). The resistance is approx. 2Ohm.
Y
N
Replace the Eject Motor
(PL
22.9).
Measure the voltage between the Finisher PWB
) (BSD 12.22). The voltage is approx. +24VDC.
Y
N
Replace the Finisher PWB
(PL
Replace the Eject Motor
(PL
22.9). If the problem persists, replace the Finisher PWB
23.16).
Replace the Finisher PWB
(PL
23.16).
Status Indicator Raps
012-259, 012-260
(PL
22.9) between each point of J8878-1/3/4/6
(PL
23.16) P8983-5/6/7/8 (+) and GND (-
23.16).

012-260 Eject Clamp Home Sensor ON Failure RAP

BSD-ON:12.22
After the Eject Clamp started ascending, the Eject Clamp Home Sensor did not turn On within
500ms.
Initial Actions
Power OFF/ON
Remove foreign substances in the Eject Clamp mechanism.
Procedure
Manually operate the Eject mechanism. The Eject mechanism moves smoothly.
Y
N
Replace the parts that are interfering with operation.
Execute
Component
Control[012-250 Eject Clamp Home Sensor]. Actuate the Eject Clamp
Home Sensor with paper. The display changes.
(PL
Y
N
Check the connections of
correctly.
Y
N
Connect
J8870
and P/J8988.
Check the wire between J8870 and J8988 for an open circuit or a short circuit (BSD
12.22). The wire between J8870 and J8988 is conducting without an open circuit or
a short circuit.
Y
N
Repair the open circuit or short circuit.
Measure the voltage between the Finisher PWB P8988-9 (+) and GND (-) (BSD 12.22).
The voltage is approx. +5VDC.
Y
N
Replace the Finisher PWB
Measure the voltage between the Finisher PWB P8988-8 (+) and GND (-) (BSD 12.22).
Actuate the Eject Clamp Home Sensor with paper. The voltage changes.
Y
N
Replace the Eject Clamp Home Sensor
Replace the Finisher PWB
Alternately execute
Component
trol[012-055 Eject Motor FWD HI]. The Eject Motor
Y
N
Check the connections of
nected correctly.
Y
N
Connect
P/J8878
and P/J8983.
A
B
February, 2008
2-134
J8870
and P/J8988.
J8870
and
P/J8988
(PL
23.16).
(PL
23.11).
(PL
23.16).
Control[012-054 Eject Motor FWD LO] and
(PL
22.9) starts up.
P/J8878
and P/J8983.
P/J8878
and
WorkCentre 5225, 5230
are connected
Component Con-
P/J8983
are con-
Launch Version

Advertisement

Table of Contents
loading

This manual is also suitable for:

Workcentre 5225Workcentre 5230

Table of Contents