012-283 (A-Finisher) Set Clamp Home Sensor ON Fail

BSD-ON:12.7
In the initialize operations each at Power On, when Interlock closed and at the start of a job,
and in the Set Clamp Motor's ejecting operation, the Set Clamp Home Sensor was not
detected turning On within a specified time after the start of the Set Clamp Motor operation.
Initial Actions
Check the Set Clamp Home Sensor is properly installed and has no foreign object and
that the actuator is not broken.
Power Off/ON.
Procedure
Check the Set Clamp mechanism for a deformed or broken part and not-seated belts. The
mechanism is free from defects and belt damage.
Y
N
Repair the Set Clamp mechanism.
Enter Component Control [012-251]. Rotate the Set Clamp Shaft by hand to block and unblock
the Set Clamp Home Sensor. The display changes.
Y
N
Check the connections of P/J8707, P/J8742B,
J8742B,
P/J8742A
and
P/J8723
are securely connected.
Y
N
Connect P/J8707, P/J8742B,
Check for an open or short circuit between J8707 and J8742B, and between J8742A and
J8723. The wires between J8707 and J8742B and between J8742A and J8723 are
OK.
Y
N
Repair the open or short circuit.
Measure the voltage between Finisher PWB J8707-9 (+) and GND (-). The voltage is
approx. +5VDC.
Y
N
Go to Wirenet A-Finisher +5VDC and check the +5VDC circuit.
Measure the voltage between Finisher PWB J8707-8 (+) and GND (-). Rotate the Set
Clamp Shaft by hand to block and unblock the Set Clamp Home Sensor. The
changes.
Y
N
Replace the Set Clamp Home Sensor
Check the wires and connectors for an intermittent open or short circuit. If the problem
continues, replace the Finisher PWB
Enter [012-017]. The Set Clamp Motor rotates.
Y
N
Check the connections of
P/J8706
and P/J8740.
connected.
A
Launch Version
WorkCentre 5225, 5230
P/J8742A
and P/J8723. P/J8707,
P/J8742A
and
P/J8723
securely.
(PL
22.4).
(PL
22.7).
P/J8706
and
P/J8740
are securely
A
Y
N
Connect
P/J8706
Check for an open or short circuit between J8706 and J8740. The
J8706 and J8740 are OK.
Y
N
Repair the open or short circuit.
Measure the voltage between Finisher PWB J8706-9 (+) and GND (-), and between
J8706-11 (+) and GND (-). Each voltage is approx. +24VDC.
Y
N
Go to Wirenet A-Finisher +24VDC and check the +24VDC circuit. If the problem con-
tinues, replace the Finisher PWB
Replace the Set Clamp Motor
PWB
(PL
22.7).
Check the wires and connectors for an intermittent open or short circuit. If the problem contin-
ues, replace the Finisher PWB
P/
voltage
February, 2008
2-111
and
P/J8740
securely.
(PL
22.7).
(PL
22.9). If the problem continues, replace the Finisher
(PL
22.7).
012-283 (A-Finisher)