012-283 (A-Finisher) Set Clamp Home Sensor ON Fail
BSD-ON:12.7
In the initialize operations each at Power On, when Interlock closed and at the start of a job,
and in the Set Clamp Motor's ejecting operation, the Set Clamp Home Sensor was not
detected turning On within a specified time after the start of the Set Clamp Motor operation.
Initial Actions
•
Check the Set Clamp Home Sensor is properly installed and has no foreign object and
that the actuator is not broken.
•
Power Off/ON.
Procedure
Check the Set Clamp mechanism for a deformed or broken part and not-seated belts. The
mechanism is free from defects and belt damage.
Y
N
Repair the Set Clamp mechanism.
Enter Component Control [012-251]. Rotate the Set Clamp Shaft by hand to block and unblock
the Set Clamp Home Sensor. The display changes.
Y
N
Check the connections of P/J8707, P/J8742B,
J8742B,
P/J8742A
and
P/J8723
are securely connected.
Y
N
Connect P/J8707, P/J8742B,
Check for an open or short circuit between J8707 and J8742B, and between J8742A and
J8723. The wires between J8707 and J8742B and between J8742A and J8723 are
OK.
Y
N
Repair the open or short circuit.
Measure the voltage between Finisher PWB J8707-9 (+) and GND (-). The voltage is
approx. +5VDC.
Y
N
Go to Wirenet A-Finisher +5VDC and check the +5VDC circuit.
Measure the voltage between Finisher PWB J8707-8 (+) and GND (-). Rotate the Set
Clamp Shaft by hand to block and unblock the Set Clamp Home Sensor. The
changes.
Y
N
Replace the Set Clamp Home Sensor
Check the wires and connectors for an intermittent open or short circuit. If the problem
continues, replace the Finisher PWB
Enter [012-017]. The Set Clamp Motor rotates.
Y
N
Check the connections of
P/J8706
and P/J8740.
connected.
A
Launch Version
WorkCentre 5225, 5230
P/J8742A
and P/J8723. P/J8707,
P/J8742A
and
P/J8723
securely.
(PL
22.4).
(PL
22.7).
P/J8706
and
P/J8740
are securely
A
Y
N
Connect
P/J8706
Check for an open or short circuit between J8706 and J8740. The
J8706 and J8740 are OK.
Y
N
Repair the open or short circuit.
Measure the voltage between Finisher PWB J8706-9 (+) and GND (-), and between
J8706-11 (+) and GND (-). Each voltage is approx. +24VDC.
Y
N
Go to Wirenet A-Finisher +24VDC and check the +24VDC circuit. If the problem con-
tinues, replace the Finisher PWB
Replace the Set Clamp Motor
PWB
(PL
22.7).
Check the wires and connectors for an intermittent open or short circuit. If the problem contin-
ues, replace the Finisher PWB
P/
voltage
February, 2008
2-111
and
P/J8740
securely.
(PL
22.7).
(PL
22.9). If the problem continues, replace the Finisher
(PL
22.7).
012-283 (A-Finisher)
wires
between
Status Indicator Raps