003-795 AMS Limit Error RAP
After auto document detection in Auto Reduce/Enlarge, the Reduce/Enlarge ratio did not fall
within the specified range (25%~400%).
Procedure
Ask customer to set the document size manually or change reduction/enlargement ratio.
Launch Version
WorkCentre 5225, 5230
003-930 300 DPI Scan RAP
Cannot scan over 300 DPI.
Procedure
Scan at 300 dpi or lower.
February, 2008
2-37
Status Indicator Raps
003-795, 003-930