024-342 IOT-ESS Communication Failure 3 RAP

A transmission failure occurred, the Packet number of the sent Message Packet is incorrect.
Initial Actions
Refer to BSD 3.1.
Procedure
Check that P/Js 402 on the MCU PWB
securely connected.
If the problem persists reload Firmware
Status Indicator Raps
024-342, 024-343
(PL
9.1) and P/J 310 on the ESS PWB
(ADJ
9.3.1).

024-343 IOT-ESS Communication Failure 4 RAP

A transmission failure occurred, the Message Length of the sent Message Packet is incorrect.
Initial Actions
Refer to BSD 3.1.
Procedure
(PL
9.2) are
Check that P/Js 402 on the MCU PWB
securely connected.
If the problem persists reload Firmware
February, 2008
2-322
(PL
9.1) and P/J 310 on the ESS PWB
(ADJ
9.3.1).