047-213 Different Finisher Detected RAP

BSD-ON:
A Different type of Finisher connection was detected.
Initial Actions
Power OFF the machine. Disconnect the Tray Module and the Finisher (if the machine has one).
Power ON the machine. If the problem is resolved, go to RAP
shoot the Duplex Module.
Procedure
Check the connection of each MCU PWB connector. The connectors are securely connected.
Y
N
Connect the connectors.
Check the connection of each Duplex Module PWB connector. The connectors are securely
connected.
Y
N
Connect the connectors.
Check the wire between J417 and J540 for an open circuit or a short circuit (BSD 1.2
BSD 3.3
Flag 3/Flag
4). The wire between J417 and J540 is conducting without an open
circuit or a short circuit.
Y
N
Repair the open circuit or short circuit.
Measure the voltage between the MCU PWB P417-A1 (+) and GND (-) (BSD 1.2
voltage is approx. +5VDC.
Y
N
Replace the MCU PWB
(PL
9.1).
Replace the Duplex PWB
(PL
8.1). If the problem persists, replace the MCU PWB
Launch Version
WorkCentre 5225, 5230

047-214 MCU Duplex Module RAP

BSD-ON:1.2/3.2
Communication error occurred between the MCU PWB and the Duplex Module.
Initial Actions
Power OFF the machine. Disconnect the Tray Module and the Finisher (if the machine has one).
077-131
or
077-307
and trouble-
Power ON the machine. If the problem is resolved, go to RAP
shoot the Duplex Module.
Procedure
Check the connection of each MCU PWB connector. The connectors are securely connected.
Y
Check the connection of each Duplex Module PWB connector. The connectors are securely
connected.
Y
Flag 2
/
Check the wire between J417 and J540 for an open circuit or a short circuit (BSD 1.2
BSD 3.3
circuit or a short circuit.
Y
Flag
2). The
Measure the voltage between the MCU PWB P417-A1 (+) and GND (-) (BSD 1.2
voltage is approx. +5VDC.
Y
(PL
9.1).
Replace the Duplex PWB
February, 2008
2-505
N
Connect the connectors.
N
Connect the connectors.
Flag 3/Flag
4). The wire between J417 and J540 is conducting without an open
N
Repair the open circuit or short circuit.
N
Replace the MCU PWB
(PL
9.1).
(PL
8.1). If the problem persists, replace the MCU PWB
077-131
or
077-307
and trouble-
Flag 2
/
Flag
2). The
(PL
9.1).
Status Indicator Raps
047-213, 047-214