123-372 Interface Sequence RAP
The initialization command from the Controller was not sent within the specified time.
Initial Actions
Power Off/On
Procedure
Disconnect and reconnect the electrical connections on the UI PWB
the ESS PWB
(PL
9.2)
If the problem persists reload Software
(ADJ
If the problem persists replace the ESS PWB
Status Indicator Raps
123-372, 123-373
(PL
11.2) and
P/J388
9.3.1).
(PL
9.2).
123-373 Channel RAP
There is an error in the channel sent from the Controller.
Initial Actions
Power Off/On
Procedure
on
Disconnect and reconnect the electrical connections on the UI PWB
the ESS PWB
(PL
9.2)
If the problem persists reload Software
If the problem persists replace the ESS PWB
February, 2008
2-652
(PL
11.2) and
(ADJ
9.3.1).
(PL
9.2).
Launch Version
WorkCentre 5225, 5230
P/J388
on