074-210 Tray 4 Lift Up Failure Rap - Xerox WorkCentre 5222 Service Manual

Tabloid black-and-white multifunction printer
Hide thumbs Also See for WorkCentre 5222:
Table of Contents

Advertisement

074-210 Tray 4 Lift Up Failure RAP

BSD-ON:7.10/7.12
After the 2TM-Tray 4 Feed/Lift Motor turned On, the 2TM-Tray 4 Level Sensor did not turn
On within the specified time.
After the TTM-Tray 4 Feed/Lift Motor turned On, the TTM-Tray 4 Level Sensor did not turn
On within the specified time.
Initial Actions
Reload paper in the tray correctly.
Remove foreign substances in the tray.
Power OFF/ON
Procedure
Remove the tray and reinstall. The Tray 4 Feed/Lift Motor can be heard.
Y
N
Execute
Component Control
[073-010 Tray 4 Feed/Lift Motor ON]. The Tray 4 Feed/Lift
Motor
(PL 12.3/PL
13.6) can be heard.
Y
N
Check the connections of P/J220A,
and
P/J549
are connected correctly.
Y
N
Connect P/J220A,
P/J661A
Remove the Tray 3 Feed/Lift Motor
(PL 12.3/PL
13.6).
Replace the Tray 3 Feed/Lift Motor with the Tray 4 Feed/Lift Motor.
Execute
Component Control
[073-010 Tray 4 Feed/Lift Motor ON]. The
Feed/Lift Motor
(PL 12.3/PL
13.6) can be heard.
Y
N
Return the Tray 4 Feed/Lift Motor to its original position.
Check the wire between J220A and J549 for an open circuit or a short circuit
(BSD 7.10
Flag 1
/ BSD 7.12
conducting without an open circuit or a short circuit.
Y
N
Repair the open circuit or short circuit.
Replace the Tray Module PWB
Return the Tray 3 Feed/Lift Motor to its original position.
Replace the Tray 4 Feed/Lift Motor
Go to the
OF 2
(SIZE SWITCH ASSY RAP).
Check the installation of the Tray 4 Level Sensor
actuator. The Tray 4 Level Sensor is installed correctly and the actuator works.
Y
N
Reinstall the Tray 4 Level Sensor.
A
Launch Version
WorkCentre 5225, 5230
P/J661A
and P/J549.
P/J220A,
P/J661A
and P/J549.
(PL 12.3/PL
13.6) and the Tray 4 Feed/Lift Motor
Tray
Flag
1). The wire between J220A and J549 is
(PL 12.6/PL
13.8).
(PL 12.3/PL
13.6).
(PL 12.3/PL
13.6) and the operation of the
A
Execute
Component Control
[071-209 Tray 4 Level Sensor]. Manually activate the Tray 4 Level
Sensor
(PL 12.3/PL
13.6). The display changes.
Y
N
Check the connections of P/J101B,
J549
are connected correctly.
Y
N
Connect P/J101B,
P/J661A
Check the wire between J101A and J549 for an open circuit or a short circuit (BSD 7.10
Flag 2/Flag 3
/ BSD 7.12
Flag 2/Flag
ducting without an open circuit or a short circuit.
Y
N
Repair the open circuit or short circuit.
Measure the voltage between the Tray Module PWB P549-A7 (+) and GND (-) (BSD 7.10
Flag 3
/ BSD 7.12
Flag
3). The voltage is approx. +5VDC.
Y
N
Replace the Tray Module PWB
Measure the voltage between the Tray Module PWB P549-A9 (+) and GND (-) (BSD 7.10
Flag 2
/ BSD 7.12
Flag
2).
Activate the actuator of the Tray 4 Level Sensor
changes.
Y
N
Replace the Tray 4 Level Sensor
Replace the Tray Module PWB
Replace the Tray Module PWB
3
February, 2008
2-539
P/J661A
and P/J549. P/J101B,
and P/J549.
3). The wire between J101A and J549 is con-
(PL 12.6/PL
13.8).
(PL 12.3/PL
13.6). The
(PL 12.3/PL
13.6).
(PL 12.6/PL
13.8).
(PL 12.6/PL
13.8).
Status Indicator Raps
P/J661A
and
P/
voltage
074-210