012-221 (A-Finisher) Front Tamper Home Sensor ON Fail

BSD-ON:12.4
During the moving of the Front Tamper, when the Front Tamper Home Sensor was Off, to the
home position, the Front Tamper Home Sensor did not detected turning On within a specified
time after the Front Tamper started moving.
Initial Actions
Check the Front Tamper Home Sensor is properly installed and has no foreign object and
that the actuator is not broken.
Power Off/ON.
Procedure
Check the Front Tamper for any foreign object, deformation and binding that prevents it from
moving. The Front Tamper is defects and binding.
Y
N
Repair the deformation and remove the foreign object(s) and the binding.
Check the drive mechanism to the Front Tamper for a deformed or broken part and not-seated
gears. The drive mechanism is free from defects and the gears seat properly.
Y
N
Repair the Front Tamper mechanism.
Run DC330[012-220].
Enter Component Control [012-220]. Move the Front Tamper by hand to block and unblock the
Front Tamper Home Sensor. The display changes.
Y
N
Check the connections of
P/J8700
and P/J8724.
connected.
Y
N
Connect
P/J8700
and
P/J8724
Check for an open or short circuit between J8700 and J8724. The
J8700 and J8724 are OK.
Y
N
Repair the open wire or short circuit.
Measure the voltage between Finisher PWB J8700-6 (+) and GND (-). The
approx. +5VDC.
Y
N
Go to Wirenet A-Finisher +5VDC and check the +5VDC circuit.
Measure the voltage between Finisher PWB J8700-5 (+) and GND (-). Move the Front
Tamper by hand to block and unblock the Front Tamper Home Sensor. The
changes.
Y
N
Replace the Front Tamper Home Sensor
Check the wires and connectors for an intermittent open or short circuit. If the problem
continues, replace the Finisher PWB
A
Launch Version
WorkCentre 5225, 5230
P/J8700
and
P/J8724
are securely
securely.
wires
voltage
(PL
22.10).
(PL
22.7).
A
Enter [012-020] and [012-023] alternately. The Front Tamper Motor rotates.
Y
N
Check the connections of P/J8710, P/J8738A and P/J8738B.
P/J8738B are securely connected.
Y
N
Connect P/J8710, P/J8738A and
Check for an open or short circuit between J8710, P/J8738A and J8738B. The
between are OK.
Y
N
Repair the open or short circuit.
Measure the voltage between Finisher PWB J8710-5 (+) and GND (-), and between
J8710-7 (+) and GND (-). The voltage is approx. +24VDC.
Y
N
Go to Wirenet A-Finisher +24VDC and check the +24VDC circuit. If the problem con-
tinues, replace the Finisher PWB
Replace the Front Tamper Motor
isher PWB
(PL
22.7).
Check the wires and connectors for an intermittent open or short circuit. If the problem contin-
ues, replace the Finisher PWB
between
is
voltage
February, 2008
2-105
P/J8710
P/J8738B
securely.
(PL
22.7).
(PL
22.10). If the problem continues, replace the Fin-
(PL
22.7).
Status Indicator Raps
012-221 (A-Finisher)
P/J8738A and
wires