REP 7.3.8 HCF Nudger Bracket/Nudger Lever/Torsion
Spring
Parts List on
PL 18.4
Removal
To avoid personal injury or shock, do not perform repair or adjustment activities with
the power switch on or electrical power applied to the machine.
1.
Remove the HCF Feed Shaft.
(REP
2.
Disassemble the Feed Shaft by removing (4) E-Rings and unscrewing the Nudger Sup-
port that retains the Torsion Spring.
Replacement
1.
Install replacement parts.
2.
Carry out the removal steps in reverse order.
Repairs and Adjustments
REP 7.3.8, REP 7.3.9
WARNING
7.3.6)
REP 7.3.9 HCF Casters
Parts List on
PL 18.8
Removal
To avoid personal injury or shock, do not perform repair or adjustment activities with
the power switch on or electrical power applied to the machine.
1.
Un-dock (remove) the HCF.
2.
Remove all paper from the HCF Tray.
3.
Roll the HCF away from the copier/printer.
4.
Turn the HCF over onto its left side to expose the casters on the underside of the HCF.
5.
Remove (3) installation screws per caster.
Replacement
1.
Install a new caster or casters, by tightening the (3) installation screws per caster.
2.
Turn the HCF back up to an upright position.
3.
Roll the HCF back toward the copier/printer.
4.
Place previously removed paper, or fresh paper, into the HCF Tray.
5.
Dock the HCF.
February, 2008
4-48
WARNING
(REP
7.3.3)
WorkCentre 5225, 5230