8.
Remove the Set Clamp Shaft.
(Figure
(1)Move Set Clamp Shaft in the direction of the arrows.
(2)Remove Belts (3) from Pulleys (3).
(3)Remove Set Clamp Shaft in the direction of the arrow.
Figure 6 Removing the Set Clamp Shaft (j0fa42277)
Replacement
1.
Reverse the removal procedure for replacement.
2.
Install and align the Eject Belts with marks on the Pulleys.
Figure 7 Installing the Eject Belts (j0fa42278)
Repairs and Adjustments
REP 22.9.2, REP 22.9.3
6)
(Figure
7)

REP 22.9.3 Eject Belts

Parts List on
PL 22.9
Removal
To avoid personal injury or shock, do not perform repair or adjustment with electrical
power applied to the machine.
1.
Remove the A-Finisher from the machine.
2.
Remove the Compile Assembly.
3.
Remove the Front/Rear Tamper Motor Assembly.
4.
Move the Eject Home Sensor Assembly.
(1)Remove Screw.
(2)Move Eject Home Sensor Assembly.
Figure 1 Moving the Eject Home Sensor Assembly (j0fa42279)
February, 2008
4-208
WARNING
(REP
22.1)
(REP
22.9.1)
(REP
22.10.1)
(Figure
1)