012-923 H-Transport Entrance Snr Static Jam B Rap; 012-935 Paper At Xport Entrance Sensor - Xerox WorkCentre 5222 Service Manual

Tabloid black-and-white multifunction printer
Hide thumbs Also See for WorkCentre 5222:
Table of Contents

Advertisement

012-923 H-Transport Entrance SNR static JAM B RAP

BSD-ON:12.14
During standby, paper was detected by the H-Transport Entrance Sensor.
Initial Actions
Remove foreign substances on the sensor.
Power OFF/ON
Procedure
Execute
Component
Control[012-190 H-Transport Entrance Sensor]. Actuate the H-Transport
Entrance Sensor
(PL
23.4) with paper. The display changes.
Y
N
Check the connections of
J8861
and J8987.
rectly.
Y
N
Connect
J8861
and J8987.
Check the wire between J8861 and J8987 for an open circuit or a short circuit (BSD
12.14). The wire between J8861 and J8987 is conducting without an open circuit or
a short circuit.
Y
N
Repair the open circuit or short circuit.
Measure the voltage between the Finisher PWB P8987-4 (+) and GND (-) (BSD 12.14).
The voltage is approx. +5VDC.
Y
N
Replace the Finisher PWB
(PL
Measure the voltage between the Finisher PWB P8987-6 (+) and GND (-) (BSD 12.14).
Actuate the H-Transport Entrance Sensor with paper. The voltage changes.
Y
N
Replace the H-Transport Entrance Sensor
Replace the Finisher PWB
(PL
23.16).
Replace the Finisher PWB
(PL
23.16).
Launch Version
WorkCentre 5225, 5230
J8861
and
J8987
are connected cor-
23.16).
(PL
23.4).

012-935 Paper at Xport Entrance Sensor

BSD-ON:12.16
Control logic reports paper at the Xport Entrance Sensor.
Initial Actions
Check for obstructions in the paper path
Check that the Finisher is dock correctly to ensure proper Transport Gate operation
Procedure
Enter
Component Control
[012-100], Finisher Entrance Sensor. Select Start. Actuate the Fin-
isher Entrance Sensor. The display changes.
Y
N
Check the connections of
correctly.
Y
N
Connect
J8869
and P/J8988.
Check the wire between J8861 and J8988 for an open circuit or a short circuit (BSD
12.14). The wire between J8861 and J8988 is conducting without an open circuit or
a short circuit.
Y
N
Repair the open circuit or short circuit.
Measure the voltage between the Finisher PWB P8988-6 (+) and GND (-) (BSD 12.16).
The voltage is approx. +5VDC.
Y
N
Replace the Finisher PWB
Measure the voltage between the Finisher PWB P8988-5 (+) and GND (-) (BSD 12.16).
Actuate the Finisher Entrance Sensor with paper. The voltage changes.
Y
N
Replace the Finisher Entrance Sensor
Replace the Finisher PWB
Replace the Finisher PWB
(PL
February, 2008
2-151
J8869
and P/J8988.
J8869
and
P/J8988
(PL
23.16).
(PL
23.4).
(PL
23.16).
23.16).
012-923, 012-935
are connected
Status Indicator Raps