Ohmmeter
Continuity
Ohmmeter
No Continuity
E
G
E
Battery
SFI (5S–FE)
INSPECTION
1.
2.
(a)
If there is no continuity, replace the VSV.
S05259
(b)
If there is continuity, replace the VSV.
S05260
(c)
Air
S05261
Air
If operation is not as specified, replace the VSV.
3.
Filter
S05262
–
VSV FOR EXHAUST GAS RECIRCULATION (EGR)
REMOVE VSV
INSPECT VSV
Inspect the VSV for open circuit.
Using an ohmmeter, check that there is continuity be-
tween the terminals.
Resistance: 33 – 39 Ω at 20°C (68°F)
Inspect the VSV for ground.
Using an ohmmeter, check that there is no continuity be-
tween each terminal and the body.
Inspect the VSV operation.
(1)
Check that air flows from ports E to G.
(2)
Apply battery positive voltage across the terminals.
(3)
Check that air flows from port E to filter.
REINSTALL VSV
Author :
SF–43
SF0E0–03
Date :
1476