SF–46
RSC
+B
Closed
+B
RSC
Open
SFI (1MZ–FE)
INSPECTION
INSPECT IAC VALVE OPERATION
Battery
(a)
Connect the positive (+) lead from the battery to terminal
+B and negative (–) lead to terminal RSC, and check that
the valve is closed.
P14290
(b)
Connect the positive (+) lead from the battery to terminal
+B and negative (–) lead to terminal RSO, and check that
the valve is open.
Battery
If operation is not as specified, replace the IAC valve.
P14289
–
IDLE AIR CONTROL (IAC) VALVE
Author :
SF081–03
Date :
1545