Toyota Camry Manual page 2771

Hide thumbs Also See for Camry:
Table of Contents

Advertisement

Ohmmeter
Continuity
Ohmmeter
No Continuity
Brush Holder Side
Length
Field Flame Side
STARTING (1MZ–FE)
3.
INSPECT FIELD COIL
(a)
Check the field coil for open circuit.
Using an ohmmeter, check that there is continuity be-
tween the lead wire and field coil brush lead.
If there is no continuity, replace the field frame.
P10588
(b)
Check the field coil for ground.
Using an ohmmeter, check that there is no continuity be-
tween the field coil end and field frame.
If there is continuity, repair or replace the field frame.
P10589
4.
INSPECT BRUSHES
Using vernier calipers, measure the brush length.
Standard length: 15.5 mm (0.610 in.)
Minimum length: 10.0 mm (0.394 in.)
If the length is less than minimum, replace the brush holder and
field frame.
5.
INSPECT BRUSH SPRINGS
Length
Check the brush spring load.
Z10079
Take the pull scale reading the instant the brush spring
separates from the brush.
Standard spring installed load:
1.2 kW
1.4 kW
Minimum spring installed load:
1.2 kW
1.4 kW
If the installed load is less than minimum, replace the brush
ST0019
springs.
STARTER
13.7 – 19.6 N (1.4 – 2.0 kgf, 3.0 – 4.4 lbf)
17.6 – 23.5 N (1.8 – 2.4 kgf, 3.9 – 5.3 lbf)
Author :
9.8 N (1.0 kgf, 2.2 lbf)
11.8 N (1.2 kgf, 2.6 lbf)
Date :
ST–9
1736

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents