C80 Series Instruction Manual
10 Troubleshooting

10.4.2 Writing and Reading the Data Using the NC Data Designation (NC Memory Diagnosis Screen)

Diagn
Mem dia
The NC internal data can be displayed and rewritten on the NC memory diagnosis (Mem dia) screen of the diagnosis (Di-
agn) screen. The custom API library's NC data read/write interface is used to display and rewrite the NC's internal data.
The contents of the NC data can be displayed by designating the part system No., section No., sub-section No. and axis
No. on this screen.
(1)
(2)
Display items
Display items
(1)
Index No.
(2)
Data contents
(3)
Memory data
IB-1501453-C
This displays the registration No. of the NC memory data. When one of the "2. Data
contents" is set, the number is highlighted indicating that the normal display of the data
contents has stopped.
Part system No.
Designate the part system No. (1: 1st part system). Designate "0" to designate the data
common for the part systems.
Section/sub-section/axis:
Designate the section No., sub-section No. and axis No. of the data to be set and dis-
played. The setting format is, section No./sub-section No./axis No.
<Note>
The axis No. "1" is handled as the first axis. Designate "0" for the data which does
not require an axis designation.
This displays the contents of the data.