Mitsubishi Electric C80 Series Instruction Manual page 429

Hide thumbs Also See for C80 Series:
Table of Contents

Advertisement

C80 Series Instruction Manual
11 Performing a Backup Operation
(12) If the file to be transferred (input) is targeted for edit lock (edit lock B: 8000 to 9999 or edit lock C: 9000 to 9999), the
message "Edit lock B" or "Edit lock C" is displayed, causing a transfer failure.
If the program name is input with only numbers when the parameter "#8936 Delete leading 0" is set to "1", the program
is checked with the leading zero deleted. (Example: If the file name to be transferred (input) is designated by "008000"
while edit lock B is enabled, the message "Edit lock B" is displayed, causing a transfer failure.)
(13) Multiple successive files or wildcard (*), if designated, is transferred, excluding the programs to be edit-locked, to suit
the status of edit lock B or C.
(14) If the device shown below and the directory are designated for the destination to transfer a file, the following opera-
tion is performed depending on conditions.
When an existing file is designated: The file is transferred with a temporary file name, and changed to the desig-
nated file name after transfer processing has been completed.
When a new file is designated: A new file is transferred with a temporary file name, and changed to the designated
file name after transfer processing has been completed.
(1) [B:Dev]: Memory, Memory2
Directory: Machining program
(2) [B:Dev]: Memory card, USB memory
A temporary file is designated by the file name that consists of 11 digits, beginning with the symbol "~".
After transfer is terminated properly, the temporary file is changed to the designated file name.
A temporary file remains in the cases below, but can be deleted in the same way as for a normal file.
When the transfer has terminated abnormally, for example, because the destination's capacity became full.
When the transfer has been interrupted.
Notes when transferring tool offset data files
(1) If an error occurs during offset data transfer, an error message appears on the screen, and the transfer operation is
interrupted.
Notes when transferring parameter files
(1) In the same manner as when setting in the Parameter screen, there are parameters validated immediately after input,
and parameters validated after a restart. Restart when a parameter file has been transferred to the NC memory.
(2) When a parameter file is transferred to the NC memory, the setting value of the input/output parameters is also
changed. Before transferring next time, set the parameters again.
Notes when transferring common variable data files
(1) If the variable value is 100000 or more or less than 0.0001 when transferring common variable data, it is expressed
with an exponential expression.
Notes when transferring all tool data files
(1) When tool life data is output from the NC memory, the tool information data, tool compensation data, and custom data
allocation information are output per section.
Tool information data section: [TOOLINF_L1] (Tool life management I), [TOOLINF_L2] (Tool life management II),
Tool compensation data section: [TOOLOFS]
Custom data allocation section: [CUSTOM]
Notes when transferring sampling data file
(1) When the output form is set as 8-digit hexadecimal number and the parameter "#1004 ctrlunit" is set to "E (1nm)",
accurate data can be output just within 1 m. When the output data length exceeds 1 m, lower 32 bits of the sampling
data will be output.
(2) Sampling data file can be transferred from NC memory to an external device (output) but cannot be transferred from
an external device to NC memory (input).
IB-1501453-C
[TOOLINF_M] (Tool life management M system)
404

Advertisement

Table of Contents
loading