9 Machining a Workpiece

9.2.3 Switching the Counter Types

Monitr
Dsp sw.
The counter mode on the monitor screen (monitor screen (normal view), monitor screen (simple view), and 2-part system
simultaneous display screen) can be switched using the parameter or the menu [Counter].
(1) Switching the counter type in the parameter setting
(2) Switching the counter type in the menu [Counter]
Switching in the parameter setting
The type of the counter to be displayed on the monitor screen can be switched using each of the counter type parameters
"#8901" to "#8905". The figure below shows the relationship between counters and parameters using arrows.
<Monitor screen (Normal view)>
#8901 Counter type 1
#8902 Counter type 2
<Monitor screen (Simple view)>
#8903 Counter type 3
#8904 Counter type 4
#8905 Counter type 5