9 Machining a Workpiece

9.2.8 Program Tree Display

Monitr
Tree
This displays the main program, subprogram, MDI interrupt and user macro call nesting structure.
This also displays the execution position of the main program and the subprogram (the lowest level of the nest only) as a
percentage during the automatic operation.
(7)
(8)
Display items
Display items
(1)
O
(2)
N
(3)
B
(4)
L
(5)
Devices
(6)
(%)
(7)
Main
(8)
1 to 8
IB-1501453-C
(1)
(2)
(3)
Program No. (0 to 15 characters) If the program No. (program name) exceeds 15 char-
acters, "*" will appear at the 15th character.
Sequence No. (0 to 99999999)
Block No. (0 to 99999)
Remaining number of subprogram repetitions (0 to 99)
Operation device (0 to 7 characters)
Displays the program storage device and MDI interruption.
Memory
Memory2
MDI (MDI interruption)
Program execution rate display
Assuming the whole machining program size as 100%, the execution position during
an automatic operation is displayed in % (percentage). When the automatic operation
is not executed, 0% is displayed for the main program's percentage display.
The subprogram's percentage is displayed only for the lowest level of the nest and oth-
er subprograms will display blank.
Main program
Called subprogram, user macro call and MDI interrupt
(4)
(5)
Details
306