C80 Series Instruction Manual
11 Performing a Backup Operation
11.8.4 Data Protection Keys
Data protection key prevents various data from being set or erased.
The key name differs according to the MTB. Refer to the instruction manual issued by the MTB for details.
The following data can be protected with the data protection key:
All tool data and the coordinate system preset data using the origin set
User parameters and common variables
Machining programs
The data protection key is enabled to prohibit the setting, erasing, etc. while the PLC signal is OFF (B contact).
Data protection key has higher protection level than that of Data protection by user's level.
11.8.5 The Batch Input/Output the Machining Program of NC Memory
Mainte
I/O
One file which consists of two or more machining program can be transferred to NC memory by dividing the file. The ma-
chining programs united with one file can be transferred to the external device.
The targets are the machining programs of the user.
Batch input and verify to NC memory
Example of "the external device -> NC memory" of machining program batch transfer
External device
(USB memory etc.)
PROCESS01
*
(Blank line)
O1000(TEST)
N1G28X0.Y0.Z0.
:
N999M02
OTAP.PRG(TAP01)
G84W-100.R0.P2000
:
M30
:
:
O9999
G92X0.Y0.Z0.
:
M30
%
When the transfer direction file name is designated, the top program name of transfer source can be omitted. ("O1000" can
be omitted in above example.)
NC memory
1000
(TEST)
N1G28X0.Y0.Z0.
:
N999M02
%
TAP.PRG
Transfer
(TAP01)
G84W-100.R0.P2000
:
M30
%
:
:
9999
G92X0.Y0.Z0.
:
M30
%
413