Mitsubishi Electric C80 Series Instruction Manual page 385

Hide thumbs Also See for C80 Series:
Table of Contents

Advertisement

C80 Series Instruction Manual
10 Troubleshooting
Display items
Control input 4H
Control input 5L
Control input 5H
Control input 6L
Control input 6H
Control output 1L
Control output 1H
Control output 2L
Control output 2H
Control output 3L
Control output 3H
Control output 4L
Control output 4H
Control output 5L
Control output 5H
Control output 6L
Control output 6H
Unit type
Unit serial No.
Software version
IB-1501453-C
This indicates the control signal input from NC to spindle. (bit8 to bitF)
BitC: M coil selection command
BitD: L coil selection command
BitE: Sub-motor selection command
This indicates the control signal input from NC to spindle. (bit0 to bit7)
This indicates the control signal input from NC to spindle. (bit8 to bitF)
BitB: Minimum excitation 2 changeover request
BitC: Speed gain set 2 changeover request
BitD: Zero point re-detection request
BitE: Increase holding power of spindle
This indicates the control signal input from NC to spindle. (bit0 to bit7)
Bit0: OMR-FF control request
This indicates the control signal input from NC to spindle. (bit8 to bitF)
Bit8: Drivers communication control request
This indicates the control signal input from spindle to NC. (bit0 to bit7)
Bit0: In READY ON
Bit1: In Servo ON
Bit7: In alarm
This indicates the control signal input from spindle to NC. (bit8 to bitF)
Bit8 to BitA: In torque limit selection
BitC: In-position
BitD: In torque limit
BitF: In warning
This indicates the control signal input from spindle to NC. (bit0 to bit7)
Bit0: Z phase passed
Bit3: In zero speed
Bit7: In external emergency stop
This indicates the control signal input from spindle to NC. (bit8 to bitF)
Bit9: In speed monitor
BitA: In door closed (controller)
BitB: In door closed (self drive unit)
This indicates the control signal input from spindle to NC. (bit0 to bit7)
This indicates the control signal input from spindle to NC. (bit8 to bitF)
This indicates the control signal input from spindle to NC. (bit0 to bit7)
Bit0 to Bit2: In spindle control mode selection
Bit4: In gear changeover command
Bit5 to Bit6: In gear selection
Bit7: Magnetic pole position not set
This indicates the control signal input from spindle to NC. (bit8 to bitF)
BitD: In L coil selection
This indicates the control signal input from spindle to NC. (bit0 to bit7)
Bit0: Current detection
Bit1: Speed detection
Bit6: In coil changeover
This indicates the control signal input from spindle to NC. (bit8 to bitF)
Bit9: 2nd speed detection
BitB: In minimum excitation rate 2 selection
BitC: In speed gain set 2 selection
BitD: Zero point re-detection complete
BitF: In 2nd in-position
This indicates the control signal input from spindle to NC. (bit0 to bit7)
Bit0: In OMR-FF control
This indicates the control signal input from spindle to NC. (bit8 to bitF)
Bit8: In drivers communication control
This displays the spindle type.
This displays the spindle serial No.
This displays the software No. and version on the spindle side.
360
Details

Advertisement

Table of Contents
loading

Table of Contents