4 Inputting and Outputting a Machining Program
Operation method (Selecting a file from a device other than the NC memory)
Press a device selection shortcut key on the I/O
(1)
screen of the edit screen.
(Example) [N]
(2)
Press the menu [File set].
By pressing the operation menu at this point, it is pos-
sible to change the device.
Only when the device functions as the memory, the
menu [Program] or [Program all] is valid.
<When selecting the file name from the list>
(3)
Move the cursor to the directory to be selected and
set.
[↑], [↓] [INPUT]
Repeat this operation until the cursor arrives at the
target directory.
Next, refer to operation (4).
<When inputting the file name from the input area>
(3)
Input the directory path.
(Example) /PRG/PRECUT [INPUT]
<When selecting the file name from the list>
Move the cursor to the file name to be selected, and
(4)
set.
[↑], [↓] [INPUT]
<When inputting the file name from the input area>
(4)
Input the file name.
10013.PRG [INPUT]
IB-1501453-C
The device name changes to "USB memory".
The root directory (/) appears in the directory.
The program list of the USB memory and the input area
appear.
The directory selected in the directory column appears.
The contents of the selected directory appear in the list.
Select ".." to move to one directory above.
There is no change when "." is selected.
The input directory path appears in the directory column.