Mitsubishi Electric C80 Series Instruction Manual page 181

Hide thumbs Also See for C80 Series:
Table of Contents

Advertisement

C80 Series Instruction Manual
5 Setting a Tool and a Workpiece
(8)
Select the X axis, and manually move the tool to the
work side face.
Jog or handle feed
Workpiece
Program zero point
Enter the name of axis to be measured, and the mea-
(9)
surement value (diameter) of workpiece.
X20.
(10) Press the menu [Measure].
Note
(1) If the parameter "#11017 T-ofs set at run" is set to "1", the tool compensation amount data during automatic operation
or during pause of operation can be measured.
(2) This setting may be disabled due to the parameter "#8933 Disable lngth comp" or "8934 Disable wear comp" setting.
For details, refer to "5.4.6 Disabling the Setting of Tool Compensation Amount".
(3) When entering data without decimal points, you can select the 1-mm (or 1-inch) data input or the input in the minimum
input unit (same as "#1003 iunit") by designating the "#8119 Comp. unit switch" parameter.
<1-mm unit: "#8119 Comp. unit switch" is "0".>
Input
1
100
10.
.012
<Minimum input unit (#1003 iunit B): "#8119 Comp. unit switch" is "1".>
Input
1
100
10.
.012
IB-1501453-C
Machine zero point
X-axis measurement
value
Tool length X
Workpiece measurement
Result
1.000
100.000
10.000
0.012
Result
0.001
0.100
10.000
0.012
156
When you enter "X", the cursor is moved to the X-axis
column.
<Note>
If you input an axis name that does not exist, the cur-
sor does not move.
The second and subsequent characters are not con-
sidered to be the axis name and, therefore, the cur-
sor does not move. (Example: If you enter "XZ", the
cursor moves on the X axis, but the cursor does not
move on the Z axis.)
Also, if anything other than tool length data is dis-
played, the cursor does not move even when the
first input value is the axis name.
Value "X20." is displayed in the input column.
The measured value (X-axis machine position - Input
value (20)) is set in the tool length data at the cursor po-
sition. The input column is cleared.