Mitsubishi Electric C80 Series Instruction Manual page 369

Hide thumbs Also See for C80 Series:
Table of Contents

Advertisement

C80 Series Instruction Manual
9 Machining a Workpiece
Previous command and command in execution
(1) When the buffer is corrected following the operation mode change at single block stop, nothing will be displayed in
previous command and command in execution.
(2) When there is no block after sub program call or user macro call, a program error occurs at the last block of the des-
tination program. If a buffer correction is made in this state, the destination program will be displayed in the buffer
correction window, but the actual correction result will be reflected on the source program.
(3) The buffer cannot be corrected when the block where the buffer is corrected is in the forward side from the block called
at another nest level. The operation message "Buffer correct not possible" appears.
The buffer can be corrected when the block where the buffer is corrected is in the rear side from the block called at
another nest level.
(a)
: The buffer can be corrected.
(b)(d) : The buffer can be corrected
because the block is in the
rear side from (a).
(c)
: The buffer cannot be corrected
because the block is in the
forward side from (b).
IB-1501453-C
(a)
M98 H 111
M30
(b)
N999
G00 X10.
G04
Z20.
G04.
Y30.
G04.
M99
(c)
N111
N112 G00 X5.0
M98 H999
(d)
M21
G01 X100.
344

Advertisement

Table of Contents
loading

Table of Contents