C80 Series Instruction Manual
11 Performing a Backup Operation
11.2 Transferring a File
Mainte
I/O
Operation method
(1)
Press the menu [Area change] to select file setting
column A.
(2)
Designate the transfer source device, directory and
file name.
(3)
Press the menu [Area change] to select file setting
column B.
(4)
Designate the transfer destination device, directory
and file name.
(5)
Press the menu [Trnsfr A→B].
(6)
Press the [Y] or [INPUT] key.
CAUTION
" ; ", "EOB", "%", and "EOR" are symbols used for explanation. The actual codes for ISO are "CR, LF" ("LF")
and "%". "%" and "EOR" are represented by "%" in ISO. The programs created on the edit screen are stored in the
NC memory in a "CR, LF" format, however, the programs created with external devices may be stored in an "LF" for-
mat. The actual codes for EIA are "EOB (End of Block)" and "EOR (End of Record)".
To prevent influence from data omission and data transformation in the communication circuit, always verify
the data after inputting and outputting machining programs.
IB-1501453-C
The designated file appears.
Multiple files can be designated in the file setting column
A. Designate the first and last file name of the target
range. A wildcard "*" can be designated for the file name.
402