Operation Sequence For Program Restart - Mitsubishi Electric C80 Series Instruction Manual

Hide thumbs Also See for C80 Series:
Table of Contents

Advertisement

C80 Series Instruction Manual
9 Machining a Workpiece

9.3.5 Operation Sequence for Program Restart

There are two types of restart, type 1 and type 2.
Restart type 1
When feed hold has been applied and reset because the tool has broken, etc., restart with restart type 1.
Press the feed hold button and retreat to the tool
change position by manual means or MDI.
Press the RESET key and suspend the present
processing.
Replace with a new tool.
Search the block to be restarted.
(Refer to "Executing Restart Search (Restart type 1)")
Turn the program restart switch ON.
Execute the manual numerical value command
(S,M,T,B)
(Refer to "Executing the MSTB Commands")
In the manual (JOG/rapid traverse) mode, move
the axes to the restart return position.
(Refer to "Returning to the Restart Position")
Turn the program restart switch OFF.
Return to the automatic operation mode.
Press the cycle start button.
Note
(1) When single block signal is OFF, the machining is restarted without stopping temporarily after the axes return to the
restart position. (The cycle starts when the automatic return by program restart is valid.)
(2) Execute "reset & rewind" for resetting.
(3) Restart search is not available for a program that has a file name consisting 33 or more characters.
IB-1501453-C
Start
If the cycle starts when the "Automatic return by
program restart" parameter ("#1302 AutoRP") is
ON, the processing is restarted after all axes
return to the restart position at the same time.
(Refer to "Returning to the Restart Position")
End
322
Machining program
Feed hold reset
Machining restart
If the tool compensation amount (tool length,
tool radius) is changed, change the tool on
tool compensation screen.
Operation on program restart screen
The following items are displayed when
restart search is completed.
• Remaining distance when the restart search
is completed
• Restart position (on local coordinates)
• Each command value of the SMTB
functions.
"RP" is displayed for the axes that have
moved to the restart position. After this, the
axis does not move in either the + or -
direction.