3 Inputting a Machining Program and Defining Variables

3.4 Registering and Editing the Fixed Cycle Program

The subprogram for the fixed cycle can be input, output and edited.
However, it may not be changed without permission from the MTB.
Refer to "Programming Manual" for details on the fixed cycle program.
CAUTION
Do not change the fixed cycle program without prior approval from the MTB.

3.4.1 Fixed Cycle Operation Parameters

To input/output or edit the data of each fixed cycle subprogram, use the Data I/O and edit screens in the same way as when
creating usual user-created work programs. In this case, the parameters must have been set. Set "1" in parameter "#1166
fixpro". If this parameter is valid, the IN/OUT and edit screens are usable only for operating a fixed cycle control subpro-
gram. During this period, program file displays only fixed cycle programs. Thus, after the fixed cycle program operation,
return the parameter to "0".
Note
(1) Parameter "#1166 fixpro" will be set to "0" when the power is turned OFF.

3.4.2 Transmitting and Erasing the Fixed Cycle Program

Transmit/erase the fixed cycle program from the Data I/O screen. Check that fixed the parameter "#1166 fixpro" is valid.
The operating procedure is the same as a user machining program.