8 Other Setups
Operation method (Canceling the origin)
(1)
Press the main menu [G92 set], and then press the
menu [Origin cancel].
(2)
Press the [INPUT] key.
(3)
Repeat step (2) for each axis.
For axes that are not to be operated, press the [↓] key
and move the cursor.
The relative position counter opens as a pop-up window.
The menu [Origin cancel] is highlighted.
The cursor appears at the 1st axis of the relative position
counter.
The same value as the machine position appears at the
cursor position.
The cursor moves to the next axis.
The pop-up window closes when the origin has been
canceled for the last axis.