3 Inputting a Machining Program and Defining Variables
Display items
Display items
(1)
Variable number
(2)
Variable value
(3)
Variable name
(4)
Input section
(*1) Address #400s common variable can be used only when the sets of common variable is "700 sets or more" and the
parameter "#1336 #400_Valtype" is "1".
(*2) When the parameter "#1316 CrossCom" is set to "1", the common variables #100100 to #700199 can be used common
to part systems. The variables shown in the table below can be used common to part systems.
Common variables 1 (When "#1316 CrossCom" = "1")
#100100 to #100199
#200100 to #200199
#300100 to #300199
#400100 to #400199
#500100 to #500199
#600100 to #600199
#700100 to #700199
This is the common variable No.
There are common variable 1(common to part systems) and common variable 2 (for
each part system) (Refer to the table below).
The #100 variables appear at the head when the power is turned ON.
If "#1052 MemVal" is set to "1" (Designate No. of common variable common to part sys-
tems), "*" is attached to the variable that is common to part systems. (Note that if there
is only one part system, "*" will not appear.)
Part system
Number of sets
One part system 700 sets
Multi-part system
600+100×n
(n = number of
set(s)
part systems)
The setting range is -999,999,999 to 999,999,999 or blank.
An exponential is displayed when 7 digits are set in the integer section and 5 digits or
more are set in the decimal section.
(Example) 1234567 -> 1.2346E+006, 0.00001 -> 1.0000E-005
The minimum setting unit that can be set is 1.0000E-099 (99 digits below decimal point).
<Note>
When the setting is "blank", the setting will be handled as "0" in the calculations.
However, when the conditional expressions EQ or NE are used, the blank will not
be handled as "0".
A variable name can be assigned for #100 to #199 and #500 to #599.
Two-byte characters such as Chinese character can be displayed, however, only sym-
bols and alphanumeric characters can be input on the screen. The maximum number
of one-byte characters is 10.
This displays details of the key input.
Equivalent to # 100 to #199 in 1st part system
Equivalent to # 100 to #199 in 2nd part system
Equivalent to # 100 to #199 in 3rd part system
Equivalent to # 100 to #199 in 4th part system
Equivalent to # 100 to #199 in 5th part system
Equivalent to # 100 to #199 in 6th part system
Equivalent to # 100 to #199 in 7th part system
89
Details
Common variable 1
Common variable 2
(common to part sys-
(for each part system)
tems)
400 to 999 (*1)
100 to 199
100100 to 700199 (*2)
400 to 999 (*1)
100 to 199 ×n
100100 to 700199 (*2)
IB-1501453-C