5. Diagnosis Screens

5.5.1 Writing/Reading the Data Using the NC Data Designation

When reading the Process parameter "#8007 Auto corner override", the following data is set.
Part system No. : 1
(Example)
Section No.
Sub-section No. : 8007
Axis name
Setting the data
(1) Using the menu cursor keys, move the
cursor to the "Part system No." position.
(2) Set the part system No.
1
INPUT
(3) Separate the section No., sub-section No.,
axis No. with a "/", and set.
126/8007/0
(4) Press the menu key Data write .
(5) Set the data, and press the INPUT key.
Reading the data
(1) Set the part system No., section No.,
sub-section No., axis No. in the same way
as step "Setting the data".
(2) Press the menu key Data read .
(Note) The cursor is constantly displayed. Using the cursor keys, the cursor can be moved to the part
system No. area, section/sub-section/axis area.
5.5 NC Memory Diagnosis Screen (NC Memory Diagn Screen)
: 126
: 0
INPUT
The cursor moves to the "Part system No." position.
The index No. is highlighted, and the set value is displayed.
The cursor moves to the right item position.
The set value appears.
The cursor moves to the right item position.
Write processing is executed.
The Index No. highlight returns to normal.
The index No. highlight is released, and the normal display of
the memory data starts.
The data format (data size, display format) of the data
displayed in the memory data differs according to the data
type to be displayed.
223