5 Setting a Tool and a Workpiece

5.6.4 Displaying the Tool Life Management Data in Group Units (L system: Tool life Management II)

The tool life management data of an arbitrary group is set and displayed.
Use the
and
keys to scroll between screens if all of the registered tools cannot be displayed on one screen.
This screen is enabled only for tool life management II ("#1096 T_Ltyp" = 2).
(1)
(2)
(4)
(5)
(6)
By setting parameter "#1107 Tllfsc", it is possible to select the life management data display mode for multiple groups.
"#1107 Tllfsc" setting value
Max. No. of registered tools
<Group 1 display mode> (#1107 Tllfsc = 0)
<Group 2 display mode> (#1107 Tllfsc = 1)
No. of display groups
(3)
0
1
16
197
(8)
(7)
1
2
2
4
8
4