Mitsubishi Electric C80 Series Instruction Manual page 287

Hide thumbs Also See for C80 Series:
Table of Contents

Advertisement

C80 Series Instruction Manual
8 Other Setups
Operation method
(1)
Press the main menu [Counter set].
Instead of the operation above, the axis name ad-
dress key can be pressed to set the counter.
(Example) [Z]
(2)
Using the [↑], [↓], or the axis name address key, move
the cursor to the axis to be set.
(3)
Input a numeric value.
(Example) 100.000 [INPUT]
If the [INPUT] key is pressed without inputting a val-
ue, zero (0) will be set.
(4)
Repeat step (3) for each axis.
For axes that are not to be operated, press the [↓] key
and move the cursor.
Note
(1) When an address such as "S", "M", "T" or "B" is used for the first character of axis name of the parameter "#1022 ax-
name2", not the MSTB window but the Counter set window is displayed for address key input.
IB-1501453-C
The relative position counter opens as a pop-up window.
The cursor appears at the 1st axis of the relative position
counter.
The relative position counter opens as a pop-up window.
The cursor appears at the designated axis (Z axis).
The cursor moves.
<Note>
If two axes or more of the same name exist such as
mixed control (cross axis control), the cursor moves
to the axis corresponding to the address key to the
axis name input first.
The set value "100.000" appears at the cursor position.
The cursor moves to the next axis.
The pop-up window closes when the counter has been
set for the last axis.