Syntax
set lldp hold-multiplier multiplier-val
Parameters
multiplier‐val
Defaults
None.
Mode
Switch command, read‐write.
Example
This example sets the transmit interval to 20 seconds and the hold multiplier to 5, which will 
configure a time‐to‐live of 100 to be used in the TTL field in the LLDPDU header.
C2(rw)->set lldp tx-interval 20
C2(rw)->set lldp hold-multiplier 5

set lldp trap-interval

Use this command to set the minimum interval between LLDP notifications sent by this device. 
LLDP notifications are sent when a remote system change has been detected.
Syntax
set lldp trap-interval frequency
Parameters
frequency
Defaults
None.
Mode
Switch command, read‐write.
Example
This example sets the minimum interval between LLDP traps to 10 seconds.
C2(rw)->set lldp trap-interval 10
Specifies the multiplier to apply to the transmit interval to determine 
the time‐to‐live value. Value can range from 2 to 10. Default value is 4.
Specifies the minimum time between LLDP trap transmissions, in 
seconds. The value can range from 5 to 3600 seconds. The default 
value is 5 seconds.