Table 12-7 show nodealias config Output Details
Output
Port Number
Max Entries
Used Entries
Status
set nodealias
Use this command to enable or disable a node alias agent on one or more ports, or set the
maximum number of alias entries per port.
Syntax
set nodealias {enable | disable | maxentries maxentries} port-string
Parameters
enable | disable
maxentries maxentries
port‐string
Defaults
None.
Mode
Switch command, read‐write.
Usage
Upon packet reception, node aliases are dynamically assigned to ports enabled with an alias
agent, which is the default setting on SecureStack C2 devices. Node aliases cannot be statically
created, but can be deleted using the clear node alias command as described in "clear nodealias
config" on page 12‐34.
Example
This example shows how to disable the node alias agent on
C2(su)->set nodealias disable ge.1.3
What It Displays...
Port designation.
Maximum number of alias entries configured for this port.
Number of alias entries (out of the maximum amount configured) already used by
this port.
Whether or not a node alias agent is enabled (default) or disabled on this port.
Enables or disables a node alias agent.
Set the maximum number of alias entries per ports. Valid range is 0 to
4096. The default value is 32.
Specifies the port(s) on which to enable/disable node alias agent or set
a maximum number of entries.