Parameters
port‐string
sid sid
Defaults
If sid is not specified, admin path cost will be reset for Spanning Tree 0.
Mode
Switch command, read‐write.
Example
This example shows how to reset the admin path cost to 0 for
C2(su)->clear spantree adminpathcost ge.3.2 sid 1
show spantree adminedge
Use this command to display the edge port administrative status for a port.
Syntax
show spantree adminedge [port port-string]
Parameters
port‐string
Defaults
If port‐string is not specified edge port administrative status will be displayed for all Spanning
Tree ports.
Mode
Switch command, read‐only.
Example
This example shows how to display the edge port status for
C2(su)->show spantree adminedge port ge.3.2
Port ge.3.2 has a Port Admin Edge of Edge-Port
set spantree adminedge
Use this command to set the edge port administrative status on a Spanning Tree port.
Specifies the port(s) for which to reset admin path cost. For a detailed
description of possible port‐string values, refer to "Port String Syntax
Used in the CLI" on page 5‐2.
(Optional) Resets the admin path cost for specific Spanning Tree(s).
Valid values are 0 ‐ 4094. If not specified, SID 0 is assumed.
(Optional) Displays edge port administrative status for specific
port(s). For a detailed description of possible port‐string values,
refer to "Port String Syntax Used in the CLI" on page 5‐2.
show spantree adminedge
.3.2 on SID 1:
ge
.3.2:
ge
SecureStack C2 Configuration Guide 7-37