set linkflap portstate
set linkflap portstate
Use this command to enable or disable link flap monitoring on one or more ports.
Syntax
set linkflap portstate {disable | enable} [port-string]
Parameters
disable | enable
port‐string
Defaults
If port‐string is not specified, all ports are enabled or disabled.
Mode
Switch command, read‐write.
Example
This example shows how to enable the link trap monitoring on all ports.
C2(rw)->set linkflap portstate enable
set linkflap interval
Use this command to set the time interval (in seconds) for accumulating link down transitions.
Syntax
set linkflap interval port-string interval-value
Parameters
port‐string
interval‐value
Defaults
None.
Mode
Switch command, read‐write.
Example
This example shows how to set the link flap interval on port
C2(rw)->set linkflap interval ge.1.4 1000
5-24 Port Configuration
Disables or enables the link flap detection function.
(Optional) Specifies the port or ports on which to disable or enable
monitoring.
Specifies the port(s) on which to set the link flap interval.
Specifies an interval in seconds. A value of 0 will set the interval to
forever.
.1.4 to 1000 seconds.