3-4 Code Reference Table

1
2
3
4
5
6
7
8
9
10
RCD1
11
12
13
14
15
16
17
FL1NC
18
FL2NC
19
INSCP
20
ICPUP
21
ICPDN
22
MATPT
23
24
25
26
RESET
27
28
29
SFNC
30
31
32
GSNC
33
34
Code
HOP
Landing hall operation panel
HCB
Hall call (landing hall call) circuit board
COP
Car operation panel
ICB
Car command board
OCB
Cartop board
SW
Contactor between the drive and motor (operation contactor)
SWA
Relay that controls the Safe Torque Off (STO) of the drive
BR
Brake resistor
Transformer that changes from ACXXXV to AC110V, used for
TR1
control
Earth-leakage circuit breaker for power control
Breaker for the main three-phase power, usually the NFB (No
QM
Fuse Breaker)
Breaker for the single-phase for control, usually the NFB (No
FU1
Fuse Breaker)
DZU
Upper leveling sensor
DZD
Lower leveling sensor
FL1
Upper door zone sensor
FL2
Lower door zone sensor
Contact B of the safe relay for the upper door zone sensor (FL1)
Contact B of the safe relay for the lower door zone sensor (FL2)
Inspection signal of the control panel
Upward inspection signal of the control panel
Downward inspection signal of the control panel
Inspection from pit
EIS
Emergency operation
UDB
Emergency upward operation button
DDB
Emergency downward operation button
External reset device
SFH
Safety hatch high voltage
SFL
Safety hatch low voltage
N. C. (Normally Closed) contact of safety (SF) hatch contactor
GSH
Gate safety hatch high voltage
GSL
Gate safety hatch low voltage
N. C. (Normally Closed) contact of gate safety (GS) hatch
contactor
DSH
Layer door safety hatch high voltage
DSL
Layer door safety hatch low voltage
Description