12-4 Operation, Storage and Transportation Environments

DO NOT expose the AC motor drive to a poor environment, such as one with dust, direct sunlight, corrosive or
inflammable gases, humidity, liquids or excessive vibration. The salt in the air must be less than 0.01 mg/cm
every year.
Installation
Location
Surrounding
Temperature
Ambient
Humidity
Environment
Altitude
Atmospheric
Pressure
Power System TN system*
Environmental
Requirement
(IEC60721)
Storage
Package
Drop
Transportation
3 mm:
9.8 m/s
2
:
Vibration
2 m/s
2
:
1 m/s
2
:
Impact
Compliance with IEC/EN 60068-2-27
IP20 OPEN TYPE
Protection
NEMA1 (met when conduit box is used)
Level
The device shall be mounted in a cabinet of at least IP54.
OVC
Overvoltage category III
*
: TN system: The neutral point of the power system connects directly to the ground. The exposed metal
1
components connect to the ground through the protective grounding conductor.
*
: Single-phase models use a single-phase three-wire power system.
2
IEC60364-1/IEC60664-1 Pollution degree 2. Indoor use only.
-10–45°C. For information on derating, see Section 12-5 Derating
Operation
Curve.
Storage and
-20–70°C
Transportation
Operation
Storage /
Below 90% RH (non-condensing)
Transportation
0–1000 m
Operation
For altitudes of 1000–2000 m, decrease the drive's rated current by
2% for every 100m increase in altitude.
86–106 kPa
*
1
2
Operation: Class 3C2; Class 3S2
Transportation: Class 2C2; Class 2S2
Storage: Class 1C2; Class 1S2
ISTA procedure 1A (according to weight) IEC60068-2-31
2 to less than 9 Hz
9 to less than 20 Hz
20 to less than 55 Hz
55 to less than 200 Hz
12-5
Chapter 12 SpecificationsEB3000