5.2.4

Precautions

■1. Precautions for operations during sequence program monitor (SFC) startup
Do not operate the following with the GOT during the sequence program monitor (SFC) startup.
Doing so may delete stored data and cause the sequence program monitor (SFC) to operate incorrectly.
• Opening and closing of the SD card cover
• Inserting or removing a SD card
■2. Precautions for devices
• The GOT cannot search for indexing devices.
• The GOT cannot monitor local devices.
■3. Precautions for setting [Locus] for line graphs
The sequence program monitor (SFC) is not available when [Locus] is set for line graphs.
For using the sequence program monitor (SFC), do not set [Locus] for line graphs.
■4. Precautions for file names (program names) of comment files to be read
Only files with the file names (program names) with one-byte alphanumeric characters are applicable to the GOT.
When project data are created on GX Developer, use only one-byte alphanumeric characters for file names (program
names).
■5. CPU with a security key
(1) When RCPU or the motion controller CPU (MELSEC iQ-R series) is used
The backup/restoration can be executed even for a CPU module to which a security key is set.
(2) When QnUDVCPU, QnUDPVCPU, Q17nDSCPU, or Q170MSCPU is used
The backup/restoration cannot be executed on the CPU on which the security key is set.
To execute the backup/restoration, check the setting of the CPU.
When the target controllers of the backup/restoration include both the CPU with the security key and the CPU without
the security key, the backup/restoration is executed only for the CPU without the security key.
5.3

Operations for Display

This section explains how to display the operation screen for the sequence program monitor (SFC) after the GOT is turned
on. The GOT must have the GOT Platform Library and GOT Function Expansion Library (system applications (extended
functions)) installed on it.
■1. Starting the sequence program monitor (SFC)
Step 1.
Turn on the GOT.
Display the sequence program monitor (SFC) screen.
The display methods include the following two types.
• Starting from the utility
For how to display the utility, refer to the following.
• Using the special function switch (Sequence program monitor (SFC)) set in the project
For how to set the special function switch, refer to the following.
Step 2.
Set the channel No., network No., station number, and CPU number in the communication setting dialog.
5 - 6
5.3 Operations for Display
GOT2000 Series User's Manual (Utility)
GT Designer3 (GOT2000) Screen Design Manual
5.4.1 ■3. Communication setting window