Access Range; Precautions - Mitsubishi Electric GOT2000 Series User Manual

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

Type
Screen No.
401
402
403
Diagnosis
404
screen
405
406
411
412
501
502
503
Maintenance
554
screen
556
557
-
Others
-
20.2.2

Access range

One GOT can monitor up to 64 CNC C80 modules by switching between them.
Up to eight GOTs can simultaneously monitor one CNC C80 module.
20.2.3

Precautions

■1. Before using the CNC monitor 2
Carefully read the manual of the connected CNC C80 and fully understand the operating procedures before using the
CNC monitor 2.
■2. CNC C80 parameters that affect the CNC monitor 2
Some CNC C80 parameters affect the display and operation of the CNC monitor 2.
Example)
No.
#1043
#1135
For the details of CNC C80 parameters, refer to the manual of the CNC C80.
20 - 4
20.2 Specifications
Screen name
Diagnosis screen (System
Configuration)
Option display
I/F diagnosis
Drive monitor
NC memory diagnosis
Alarm
Self diagnosis
Data sampling
Maintenance screen
Parameter
Input/Output (Maintenance
screen)
Absolute position setting
Servo diagnosis
Diagnosis data collection setting
Menu list
Specify the screen No.
Name
lang
unt_nm
Set and display NC diagnosis data.
The configuration screen is selected.
Display the configurations of hardware and software (software No. and version).
Display the details of the options registered to the CNC.
Set and display the input and output signals of a ladder program.
Display drive diagnosis information (about the servo axis, spindle, and power
supply unit).
Set and display NC internal data.
List the current active alarms and their messages.
Display the hardware status and operation stop status.
Set the sampling parameters, and sample the NC internal data.
Format the NC memory, and set the absolute position parameters.
Set and display the user parameters and machine parameters.
Perform data input or output between the NC memory and an external I/O
device.
Set the absolute position of servo axes (NC axes and PLC axes).
Display information about a servo/spindle drive unit, including the number of
alarms, DA output information, PLG diagnosis (spindle), and alarm cause
counter.
Configure the history data collection settings, and start or stop collecting the
history data (about NC keys, alarms, and others).
List the menu configurations of all screens.
Set a screen number.
Select language displayed
Unit name
Description
Description

Advertisement

Table of Contents
loading

Table of Contents